Setting Up a Benchmark Filter

Use the Benchmark Filter settings to configure multiple profiles on which to compare current incoming quotes against one or more Makers’ quotes.

Note: Settings are arranged in a hierarchy, which means that they are executed from the top (or first row) down.

  1. Open the Hub web-based application.
  2. Click Settings > Symbol Settings from the dropdown menu.
  3. Scroll to Benchmark Filter Configuration and expand the section.
  4. Configure the settings as follows:

Settings

Description

Benchmark Profiles

Name

Type a unique name for the filter profile.

Guidelines:
  • Alphanumeric characters are supported.
  • Spaces are not supported.

Maker Stream ID

  1. Click on the field to open the window to add the Makers that will be used to create the benchmark profile for the filter.
  2. Select a Maker from the dropdown.
  3. Continue to add rows and Makers until the list is complete.
  4. Click to close the window.

Mappings

Maker Stream ID

Select the Maker on which to create this mapping from the dropdown.

Guideline: Regex, wildcard (*), and value are supported.

Core Symbol

Select a symbol from the dropdown.

Guidelines:
  • Used to test if the symbol matches this rule.
  • Regex, wildcard (*), and value are supported.

Symbol Group Path

Select the symbol group from the dropdown.

Guidelines:
  • Used to further restrict symbols by their symbol group path.
  • Wildcard (*) is supported by itself, or within the path, e.g. BAML/MAJORS/*.

Filter Name

Type a unique name to identify this mapping.

Guidelines:
  • Alphanumeric characters are supported.
  • Spaces are not supported.

Enabled

Select to enable benchmark quote filtering for this mapping.

Quote Check Method

Select the method to determine how the top-of-book (TOB) quotes from the Makers in the Benchmark Profile are used:

  • Average: Compares the current quote to the average of all Makers configured in the benchmark profile. If the current quote, in points or percentage, is different from the average of the benchmark Makers by filter value, the quote is deactivated.
  • Compare:Compares the current quote against the Makers configured in the benchmark profile. The current quote is compared to each benchmark Maker individually. If the current quote delta, in points or percentage, is away from more than the number of benchmark Makers configured in the Benchmark Maker Comparison Check, the quote is deactivated.

Filter Style

Select the option for determining how the delta is measured:

  • Points
  • Percentage

Filter Value

Indicate the value for measuring the delta for deactivating a quote.

 

Guideline: When the Filter Style is points, each point reflects a change in the value of the last digit as defined per symbol in Price Precision Decimal Places in the settings. For example 10 points applied to a symbol configured with 3 precision decimal places is interpreted as 0.010.

Benchmark Profile Name

Select the Benchmark Profile to use for this mapping.

Benchmark Maker Comparison Check

  • Indicate the number of Makers that the current quote must be within to be accepted (not deactivated.
  • Use when the Quote Check Method is set to Compare.
  • Set to 0 to have the current quote delta checked against every benchmark marker currently quoting. The delta must be within all of the currently quoting benchmark makers for the quote to be promoted to the quotebooks.
  • This field is inactive if the Quote Check Method is set to Average.
Guidelines:
  • The compare filter requires this many Maker’s TOB quotes to be within the delta of the current quote, or else it is deactivated (or filtered).
  • When set to 0, the current quote delta must be within all of the currently quoting benchmark Makers.
  • The number of quoting benchmark Makers must be greater than or equal to this value.
Explanation:
  • Benchmark Profile: Gold = 5 Maker Stream IDs
  • Mapping: Quote Check Method = Compare.
  • Benchmark Profile Name = Gold.
  • Value for Benchmark Maker Comparison Check must be <=5.
  • If value for Benchmark Maker Comparison Check > 5, the filter will not work.

Example: If the Benchmark Maker Comparison Check is set to 3 and there are 5 benchmark Makers, the current quote delta much be within 3 out of the 5 benchmark Makers in order to be accepted. If, however, the current quote delta is within only 2 out of the 5 benchmark Makers, it is deactivated.

 

Reference: See the explanation and example for the Compare Quote Check Method.

Deactivation Alert Threshold

Enter a value. When this number of filtered quotes exceeds this value, an alert message is logged Disable if set to "0".

 

Note:The number of filtered quote events is cumulative and only resets to 0 upon restart, or if some parameter of the corresponding filters change and the settings are applied at runtime.